This truck refrigeration units repair manual is suitable for standard model. Information of some option items might not be included in this manual, which you need to consult our technical service department of the company.
Here is a chart for you to check out your truck refrigeration units why not refrigerating or why refrigerating not enough.
You can check it by yourself, and you can also contact us for truck refrigeration units repair manual or change the truck refrigeration units' spare parts for a great working performance.
PHOTO: truck refrigeration units spare parts
Problems |
Possible Reasons |
|
|
Truck |
Evaporator fans working |
Condenser fan not work, compressors work |
Check out whether the fans contact fall off or not, fans whether damage or not and ground wire whether working or not.
|
Both condenser fans and compressors not working |
Check out temperature detect switch (TDS) whether damage or not, electric relay whether pull in or not,and its contact whether loose. |
||
Condenser fans working, compressors not working |
|
||
Evaporator
|
Both condenser fans and compressors working |
Check out whether speed-control switch working or not, fan lines whether break or not, and blower ground lines whether damage or not. |
|
Both condenser fans and compressors not working |
|
||
Compressors working |
Evaporator fans and condenser fans working |
Fill too much refrigerant,check it whether meet the standard amounts with high and low pressure controller
|
|
Not using truck reefer units for a long time, and check whether it still has refrigerant or not. |
|||
Truck |
Compressors working |
|
Liquid receiver inlet and outlet connect inversely. |
|
Check whether condenser surface blocked by filth. |
Chart 1: truck refrigeration units problems for self-checking and repair manual
Problems |
Reasons |
Self-checking |
At the beginning, it refrigerates well, but after a while using refrigerating effect decline; the high and low pressure data is lower. |
|
|
|
|
Change expansion value, refill in refrigerant. |
Outlet air not cooling and compressor temperature increasing; the pointer in low pressure controller downs quickly nearly to “0 “and high pressure reading more increasing. |
Expansion value filter screen is blocked by mess, and it frosts in expansion value or the expansion value “sweats”. |
|
|
Expansion value orifice has no effect. |
|
|
Drying agent in reservoir is saturate; expansion throttle is blocked by ice. |
|
Start off the freezing system, only has air flowing but cold air, and high and low pressure controller no reading. |
TDS poor contact or compressor electromagnetic clutch wire damages. |
|
Chart 2: truck refrigeration units common problems for repair manual
Item |
Fault Code |
Diagram Display |
Solutions |
|
Inner temp. sensor |
|
|
Refrigeration mode when set temperature |
|
Defrost temp. sensor |
Defrost temp. sensor open |
|
|
|
Refrigerant |
High pressure fault:HP |
|
|
|
Power voltage |
Under DC 19V / DC10V : LUEr |
|
|
|
Temp. abnormal alarm |
High Temp Alarm: HA Low Temp Alarm:LA |
|
No variation in output. |
|
Stand-by |
Stand-by model cannot |
|
Chart 3: truck refrigeration units fault code and solutions
PHOTO: Fault code displays in Control Panel
Conclusion